The UPS AND 2 thanks to microprocessor control is an ideal protection solution thanks to its perfect sinusoidal current and fully protected flow. It also provides effective protection for particularly sensitive loads such as server or even video surveillance, telephone sets, VOIP, etc.In case of power failure, the E 2 LCD line offers up to 60 minutes of backup time, thus ensuring an uninterrupted service or critical data backup.
The built-in charger only takes 4 hours to achieve maximum backup capacity. When the UPS is not on, the cold start function allows the emergency startup of the connected hardware. Upon power recovery, the UPS automatically restarts and does not require any operator intervention.
The battery is automatically charged when è is present with the mains power supply and the UPS è off. This feature, available throughout the range, ensures that when the connected devices are not in use and the UPS is switched off, the battery continues to charge. The real energy savings are achieved thanks to the advanced charger that allows the batteries to charge twice the speed à normal.
Technical specifications- Technology: Line Interactive with pure sinusoidal wave
- Power: 1500 VA
- Power factor: 0.7
- IEC 320 C 14 plug-in
- Electrical outlets: 6 IEC 320 C13 backup outlets
- Tel./ADSL protection line RJ 11 / 45 (1 -IN / 1 -OUT)
Protection and filtering- Output form: pure sinusoidal
- Protection: not loading / overloading / overvoltage + line Tel./ADSL
- Input protection: automatic switch
- Overvoltage protection: phase-neutral protection 1 kV; phase-earth and neutral ground protection: 2 kV
Dimensions - Width: 205 mm
- Depthà: 146 mm
- Height: 397 mm
Technical characteristics input- Voltage: 220 / 230 / 240 V AC
- Voltage range: 162 - 290 V AC
- Frequency: 50 / 60 Hz (automatic detection)
Exit technical characteristics- Voltage: 220 / 230 / 240 V AC
- Automatic voltage adjustment: ± 10 %
- Frequency: 50 or 60 Hz ± 1 Hz
Battery- Battery charger: automatic charging of the battery at the time of connection to the power grid
- Cold start (without network): sì
- Battery type and number: 12 V / 9 Ah x 2
- Charging time: 4 - 6 hours at 90 % after total discharge 10 hours at 90 % after total discharge
- Backup time (load 1 PC- 120 W): 30 minutes
Display- LCD Screen: Mode à Network Power, Mode à Battery, Output Charge Level, Battery Level, Input Voltage, Output Voltage, Overload, Failure & Download Battery
Alarm- Modelità battery: sound every 10 seconds
- Modelità low battery: sound every second
- Overload: Play every half second
- Battery replacement: sound every 2 seconds
- Error: Continuous sound
Communication- With USB communication port
- With RS 232 communication port
- Communication software: InfoPower (supports Windows 2000 / 2003 / XP / Vista / 2008 , Windows 7 , 8 , Linux, Unix et MAC)
Environmental features- Ideal environment: 0 - 40 °C, humidity à relative 0 - 90 % (without condensation)
- Noise level: < 40 dB
Package contents- 1 x continuità group; EUCI 2 LCD 1500
- 3 x IEC output cables
- 1 x USB cable
- 1 x RJ cable 11
- 1 x User manual